Call 08047640151 61% Response Rate

our range

Vacuum Gauge

Offering you a complete choice of products which include vacuum gauge.
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
  • Vacuum Gauge
Vacuum Gauge

Vacuum Gauge

Rs 1,850  / PieceGet Best Price
Dial Size6 inch / 150 mm
Brandsunflow
Pressure Range-1 to 0 bar(-15 to 0 psi)
UseVacuum
Display TypeAnalog
Connection Typebsp npt thread etc
Bourdon Vacuum GaugeThe inside of a tube which is bent into a circular arc (the so-called Bourdon tube) is connected to the vacuum system. Due to the effect of the external atmospheric pressure, the end of the tube bends more or less during the evacuation process. This actuates the pointer arrangement which is attached to this point. The corresponding pressure can be read off on a linear scale. With Bourdon gauges it is possible to roughly determine pressures between 10 mbar (7.5 Torr) and atmospheric pressure.
Capsule Vacuum GaugeThis vacuum gauge contains a hermetically sealed, evacuated, thin-walled diaphragm capsule which is located within the instrument. As the vacuum pressure reduces, the capsule bulges. This movement is transferred via a system of levers to a pointer and can then be read off as the pressure on a linear scale.
Diaphragm Vacuum GaugeIn the case of the diaphragm vacuum gauge which is capable of absolute pressure measurements, a sealed and evacuated vacuum chamber is separated by a diaphragm from the vacuum pressure to be measured. This serves as the reference quantity. With increasing evacuation, the difference between the pressure which is to be measured and the pressure within the reference chamber becomes less, causing the diaphragm flex. This flexure may be transferred by mechanical means like a lever, for example, to a pointer and scale, or electrically by means of a strain gauge or a bending bar for conversion into an electrical measurement signal. The measurement range of such diaphragm vacuum gauges extends from 1 mbar (0.75 Torr) to over 2000 mbar (1500 Torr).
Capacitance Vacuum GaugeThe pressure sensitive diaphragm of these capacitive absolute pressure sensors is made of Al2O3 ceramics. The term “capacitive measurement” means that a plate capacitor is created by the diaphragm with a fixed electrode behind the diaphragm. When the distance between the two plates of this capacitor changes, a change in capacitance will result. This change, which is proportional to the pressure, is then converted into a corresponding electrical measurement signal. Here too, an evacuated reference chamber serves as the reference for the pressure measurements. With capacitance gauges it is possible to accurately measure pressures from 10-5 mbar/Torr to well above atmospheric pressure, whereby different capacitance gauges having diaphragms of different thickness (and therefore sensitivity) will have to be used.
Vacuum Gauges where the Pressure Readings Depend of the Type of Gas
Thermal Conductivity Gauge (Pirani)This measurement principle utilizes the thermal conductivity of gases for the purpose of pressure measurements in the range from 10-4 mbar/Torr to atmospheric pressure. The filament within the gauge head forms one arm of a Wheatstone bridge. The heating voltage which is applied to the bridge is controlled in such a way, that the filament resistance and thus the temperature of the filament remains constant regardless of the quantity of heat given off by the filament. Since the heat transfer from the filament to the gas increases with increasing pressures, the voltage across the bridge is a measure of the pressure. Improvements with regard to temperature compensation have resulted in stable pressure readings also in the face of large temperature changes, in particular when measuring low pressures.
Cold Cathode Ionization Vacuum Gauge (Penning)Here the pressure is measured through a gas discharge within a gauge head whereby the gas discharge is ignited by applying a high tension. The resulting ion current is output as a signal which is proportional to the prevailing pressure. The gas discharge is maintained also at low pressures with the aid of a magnet. New concepts for the design of such sensors permit safe and reliable operation of these socalled Penning sensors in the pressure range from 10-2 to 1 x 10-9 mbar/Torr.

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES